Risk of low-frequency ultrasound stimulation: Response to Brain injury during focused ultrasound neuromodulation for substance use disorder

Authors

  • Fozilxo’jayeva Aziza Bahodir qizi Student in Kimyo International University in Tashkent Author

Keywords:

Low-frequency ultrasound stimulation, transcranial focused ultrasound (tFUS), neuromodulation, brain injury, substance use disorder, ultrasound safety, acoustic exposure, mechanical index, inertial cavitation, focused ultrasound, non-invasive brain stimulation, adverse effects, neurostimulation, safety assessment, clinical translation

Abstract

Low-intensity transcranial focused ultrasound (tFUS) stimulation is an emerging non-invasive neuromodulation technique with potential applications in the treatment of neurological and psychiatric disorders, including substance use disorders. However, recent reports of serious adverse events have raised important questions regarding the safety of low-frequency ultrasound protocols and the influence of acoustic exposure parameters on brain tissue. This letter addresses concerns arising from a previously reported case of brain injury during focused ultrasound neuromodulation for substance use disorder and emphasizes the importance of detailed characterization of sonication parameters when evaluating the safety of tFUS. Particular attention is given to acoustic intensity, mechanical index, ultrasound frequency, and other exposure characteristics that may influence the likelihood of unintended bioeffects, including inertial cavitation. The authors acknowledge the limitations associated with incomplete reporting of acoustic parameters in earlier studies and highlight the need for standardized and transparent reporting to facilitate meaningful comparisons across experimental protocols. Importantly, the reported adverse event should be interpreted within the context of the specific ultrasound system, stimulation parameters, and treatment conditions rather than being generalized to all forms of low-intensity ultrasound neuromodulation. The available evidence supports continued investigation of tFUS while emphasizing rigorous safety assessment, precise acoustic characterization, appropriate exposure limits, and systematic monitoring of adverse effects. Further experimental and clinical research is required to establish parameter-specific safety margins and to support the responsible translation of low-frequency focused ultrasound neuromodulation into clinical practice.

References

1.Bishay AAED, Schafer S, Bystritsky A, Tyler WJ, Monti MM, Kubanek J, Sanguinetti JL, Spivak NM. Risk of low-frequency ultrasound stimulation: Response to “Brain injury during focused ultrasound neuromodulation for substance use disorder”. Brain Stimul. 2026;19(3):103091. doi:10.1016/j.brs.2026.103091.

2.Rezai A, Ranjan M, Bhagwat A, Arsiwala T, Carpenter J, Schafer M, Adams G, Marton J, Tirumalai P, Farmer D, Mahoney J, Finomore V. Brain injury during focused ultrasound neuromodulation for substance use disorder. Brain Stimul. 2025;18(6):2050-2053. doi:10.1016/j.brs.2025.10.012.

3.Aubry JF, et al. ITRUSST consensus on biophysical safety for transcranial ultrasonic stimulation. Brain Stimul. 2025.

4.Martin E, et al. ITRUSST consensus on standardised reporting for transcranial ultrasonic stimulation. Brain Stimul. 2024.

5.Murphy KR, et al. A practical guide to transcranial ultrasonic stimulation from the ITRUSST consortium. Clin Neurophysiol. 2025.

6.Sarica C, et al. Human studies of transcranial ultrasound neuromodulation. Brain Stimul. 2022.

7.Pasquinelli C, Hanson LG, Siebner HR, Lee HJ, Thielscher A. Safety of transcranial focused ultrasound stimulation: A systematic review of the state of knowledge from both human and animal studies. Brain Stimul. 2019;12(6):1367-1380. doi:10.1016/j.brs.2019.07.024.

8.Lee W, Weisholtz DS. Safety review and perspectives of transcranial focused ultrasound brain stimulation. Brain Neurorehabil. 2021;14(1):e4. doi:10.12786/bn.2021.14.e4.

9.Qin PP, et al. The effectiveness and safety of low-intensity transcranial ultrasound stimulation: A systematic review of human and animal studies. Neurosci Biobehav Rev. 2024;156:105501. doi:10.1016/j.neubiorev.2023.105501.

10.di Biase L, Falato E, Di Lazzaro V. Transcranial focused ultrasound (tFUS) and its applications in neuromodulation: From theoretical principles to stimulation practices. Clin Neurophysiol. 2019.

11.Zhang T, et al. A review of the excitatory and inhibitory effects on brain activity of transcranial focused ultrasound stimulation. Front Neurosci. 2021.

12.Fouragnan E. Response to: Brain injury during focused ultrasound neuromodulation for substance use disorder. Brain Stimul. 2026;19(1):102989. doi:10.1016/j.brs.2025.102989.

13.Pauly KB. Letter to the Editor in response to “Brain injury during focused ultrasound neuromodulation for substance use disorder”. Brain Stimul. 2025;18(6):2075-2076. doi:10.1016/j.brs.2025.11.004.

14.Rezai A, Ranjan M, Bhagwat A, Arsiwala T, Carpenter J, Schafer M, Adams G, Marton J, Tirumalai P, Farmer D, Mahoney J, Finomore V. Further clarification regarding brain injury during focused ultrasound neuromodulation for substance use disorder. Brain Stimul. 2026;19(1):103014. doi:10.1016/j.brs.2025.103014.

15.Zubair M. Re: Rezai A, Ranjan M, Bhagwat A et al. “Brain Injury During Focused Ultrasound Neuromodulation for Substance Use Disorder”. Brain Stimul. 2026;19(2):103030. doi:10.1016/j.brs.2026.103030.

Downloads

Published

2026-09-28